Magnetic Bead Method DNA RNA Plate Extraction Magnetic Separation Rack for 96-Well Deep Well Plate
Features | Description |
Name | 8-Strip Tip Rod Magnet Rack (2.2mL, U-bottom) |
Material | Polypropylene |
Color | Natural White |
Well number | 8-Well Square Well RNa Extraction Plate |
Well shape | Square Well |
Bottom shape | U shape |
Well Volume | 2.2 mL |
Well Identifier | Alphabetical / figure sorting |
Sterilization | Optional |
Lid | Optional |
Individual warp | Optional |
Count unit | Plate |
Qty | 2 plates / bag, 200 pcs / carton |
Sealing method | Adhesive sealing film, Heat sealable film, Silicone sealing mat with plate |
Relevant product | 2.2ml 96 Square Well Conical Bottom P-2.2-SQ-96 / P-2.2-SQG-96 |
No. | Product Features |
1 | Microplanes can be stored under subzero temperature from -40 to -80ºC |
2 | Maximum sustainable centrifuge force 4000g |
3 | Autoclavable at 20Psi, 121ºC for 20 minutes.Great heating uniformity |
4 | Minimum residual liquid; low heavy metal content |
5 | Used high quality, imported PP material for high stability, ensuring no chemical reactions with test reagents. Compatible with DMSO and inert to water |
6 | Certified DNase/RNase and Pyrogen Free |
7 | Conformed to automatic instrument |
8 | Three options for plate sealing: adhesive seals, mat caps, and heat seals. No leakage. |
9 | Good flatness, can be transported for long distance after sealing by heat sealable film |
10 | Produced and packed in Class 100,000 clean workshop |
11 | Alphabetical sorting and cut angle mark for convenient tracking of samples |
12 | Each package has a separate article number/batch number identification, facilitating the quality tracking |
High quality polypropylene (PP), good chemical resistance and heat-resistance;
With a good chemical compatibility, complete Board no bubble, no stripes, no spills, high mechanical strength,
solid bond Department;
Accommodate even larger working volumes,up to 1.2 mL or 2.2 mL storage volume per well;
Proteins and DNA will not adhere to PP, allowing for complete sample recovery.
Natural color makes it easy to locate the notch design.
Usage: Applicable to the identification system, HTS, master sampling and sample, mechanical sampling and automatically moved fluid system; Applicable to the biological field, such as PCR, RIA, EIA and cell culture, etc.;
Applicable to most polar organic solvents, acid and alkaline solutions, laboratory liquid storage.
A-Gen P-MT-8U 8-strip Tip Rod 96-Well Magnet Rack can be used for DNa RNa plate extraction by magnetic beads separation method. Pyramid-bottom eases sample retrieval and improves mixing within well by creating a sloshing effect rather than a vortex when agitated. Polypropylene construction offers a low binding surface to prevent samples from sticking to side walls.